晶闸管的擎住电流与维持电流

Thyristor Latching Current and Maintain Current

  • 摘要: 晶闸管的擎住电流和维持电流对于晶闸管的工作有重要的影响.利用晶闸管的导通特性,从载流子的角度推导出擎住电流的计算公式;通过对NPN晶体管电流增益的分析,得到维持电流的表达式.将计算结果与Sentaurus TCAD软件仿真结果对比,发现两者符合较好,验证了计算公式的正确性.

     

    Abstract: Thyristor latching current and maintaining current have important effects on its working state. With thyristor conduction characteristics latching current is derived from carrier density; Based on current gain of NPN transistor, maintaining current is obtained. Compared with simulation results of Sentaurus TCAD software, calculated results have good agreement. It shows correctness of the formula.

     

/